Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OF 99-9 — Xerox Phaser 7760

Code: OF 99-9

Description: Multiple Wire Motor For use on DC motors that: • have 1 or 2 DC power inputs • are controlled by 2 or more drivers • have no DC COM connections for return power • have no specific feedback circuits
Remedy: Connect black meter lead to ground. Measure voltage at each pin of J2 (example only, refer to the actual Circuit Diagram for the correct voltage and connector designation). +24 VDC is measured at each pin. Y↓N→Disconnect J2. Measure voltage at P2-1 and P2-6 (refer to HVPS, +24V LVPS T10 Plug/Jack Locations ). +24 VDC is measured. Y↓N→Turn the machine Off then On. Measure voltage at P2-1 and P2-6. +24 VDC is measured. Y↓N→If an interlock circuit is present, check the interlock circuit. Repair as required. If the interlock circuit is good, replace the PWB. Check the motor wires for a short circuit. If the wires are good, replace the Motor. Check the motor wires for obvious damage. If the wires are good, replace the Motor. Replace the PWB.

← Xem tất cả mã lỗi Xerox Phaser 7760

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie