Code: 309.609
Description: Tray 1 (MPT)/ 2/ 3/ 4/ 5 Feed/ Retard/ Nudge Roll The Tray 1/ 2/ 3/ 4/ 5 Feed/ Retard/ Nudge Roll has reached the end of life.
Remedy: If this fault occurs at an unexpected time or if this fault does not occur at expected timing, check steps 4 and 5 in the notes. 1. Replace the Feed/ Retard/ Nudge Rollers following the appropriate REP: • 309-609-1: Tray 1(MPT) • 309-609-2: Tray 2 • 309-609-3: Tray 3, 3TM, TTM • 309-609-4: Tray 4, 3TM, TTM • 309-609-5: Tray 5, 3TM, TTM 2. Reset the HFSI counter for the tray the rollers were replaced in. From the Control Panel menu, select Printer > Tools > Setup > Service Tools > Reset HFSI > Feed Rollers X Counters. 3. HFSI counters can be accessed through Service Diagnostics in dc135 CRU/HFSI Status and Reset to determine life remaining. NOTE: 1. If the retard roller is being replaced for multi-pick failures and the failures continue with the new retard roller, replace the friction clutch PL 9.5 item 19 or, for Tray 1/MPT, PL13.4 item 5. 2. If the Tray 1/MPT Pick Roller is replaced for pick failures and the failures continue with the new Roller, replace the Oneway Clutch (PL 13.3 Item 14 & PL 13.3 Item 15). 3. The Tray 1/MPT Feed/ Retard/ Nudge Rollers are a different part than the Feed/ Retard/ Nudge Rollers for Trays 2, 3, 4, 5. The surface texture is different because the Tray1/MPT Rollers rotate in a direction opposite that of the other trays. 4. Feed Roller life for Tray 1/MPT is 100K feeds. If this fault occurs before 100K feeds, just reset the HFSI counter. 5. Feed Roller life for Trays 2, 3, 4, 5 is 300K feeds. If this fault occurs before 300K feeds, just reset the HFSI counter.