Mã lỗi 310.330 — Xerox Phaser 7800

Code: 310.330

Description: Fuser Motor Fault. The Fuser Drive Motor revolution failure was detected.
Remedy: • Turn the power Off and check whether the Fuser Assembly is installed properly. • With the Fuser in closed state, rotate the Roller manually to check for loading.
Turn the power Off and remove the Rear Upper Cover. Disconnect the connector P592 of the MD PWB and open the Chassis Assembly. Turn the power On and enter Service Diagnostics Menu (Entering Service Diagnostics). Turn On dc330 Component Control [010-006] (Fuser Drive Motor). Does the Fuser Drive Motor rotate? Y↓ N→Is the voltage between the Fuser Drive Motor P/J242-1 (+) and the GND (-) +24VDC? Y↓ N→Go to +24VDC Power RAP. Is the voltage between the Fuser Drive Motor P/J243-1 (+) and the GND (-) +5VDC? Y↓ N→Go to +5VDC Power. Turn the power Off and check the connection between the MD PWB P/J525 and the Fuser Drive Motor P/J243 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • Fuser Drive Motor • MD PWB • MCU PWB Press the Stop button. Check the operation of dc330 Component Control [094-012] (1st BTR Contact) and dc330 Component Control [094-013] (1st BTR Retract) alternately. Does the Fuser Drive Motor rotate? Y↓ N→Turn the power Off and check the 1st BTR Contact/Retract Gear for blockage or damage. Turn the power Off and check the connection between the Fuser Drive Motor P/J243-8 and the MD PWB P/J525-A1 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • MD PWB • MCU PWB

← Xem tất cả mã lỗi Xerox Phaser 7800

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie