Mã lỗi 310.372 — Xerox Phaser 7800

Code: 310.372

Description: Heat Roll STS Center Over Temperature Fault. The AD value of the Center Thermistor was detected to be higher than the defined value 4 times in a row.
Remedy: • Turn the power Off and remove the Fuser Assembly. Check whether foreign substances or paper is wound around the Heat Roll. • Inspect the Drawer Connector between the Fuser Assembly and the Main Unit ( DJ600) for broken/bent pins, foreign substances, burns, and etc. • Check whether the MCU PWB connector P/J431 is connected properly.
Check the following connections for short circuits and poor contacts. • Between DJ600-A5 and MCU PWB P/J431-7 • Between DJ600-A4 and MCU PWB P/J431-8 If no problems are found, replace the following parts in sequence: • Fuser Assembly • MCU PWB