Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 310.398 — Xerox Phaser 7800

Code: 310.398

Description: Fuser Fan Fault. The Fuser Fan error was detected.
Remedy: Rotate the Fuser Fan manually to check for loading.
Enter dc122 Fault History. Has 041-350 faults (MD PWB F7 Open) occurred? Y↓ N→Enter Service Diagnostics menu (Entering Service Diagnostics). Turn On dc330 Component Control [042-025] (NOHAD FAN Failure Detection). Is the Fuser Fan rotating and does the test return a fuser fan error? Y↓ N→Turn the power Off and check the connection between the Fuser Fan P/J230-4/3/1 and the MD PWB P/J524-10/11/13 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • Fuser Fan • MD PWB • MCU PWB Replace the Fuser Fan. Press the Stop button and turn the power Off. Check the connection between the Fuser Fan P/J230-2 and the MD PWB P/J524-12 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • MD PWB • MCU PWB Go to the 341.350 RAP.