Code: 312.211
Description: Stacker Tray Fault. Stack Height Sensor 1 is not On within the specified time after stacker tray starts elevating. While Stacker Tray is elevating or lowering, the state of the Encoder Sensor does not change within the specified time.
Remedy: • Check for obstructions under the tray. • Check the operation of the Stacker Height Sensor 1 actuator. • Check the tray raise/lower mechanism for damage or contamination.
Execute dc330 Component Control [012-264], Stacker Height Sensor 1. Actuate the Stacker Height Sensor 1. The display changes. Y↓ N→Check the wire between J8873 pin 2 and P/J8988 pin 17 for an open or short circuit, or a loose or damaged connector. The wire is OK. Y↓ N→Repair/reconnect as required. Measure the voltage between P/J8988, pins 16 and 18 on the Finisher PWB (Stacker Tray Control). The voltage is approx. +5VDC. Y↓ N→Replace the Finisher PWB. Measure the voltage between P/J8988, pin 17 on the Finisher PWB and GND (Stacker Tray Control). Actuate the Stacker Height Sensor 1. The voltage changes. Y↓ N→Replace the Stacker Height Sensor 1. Replace the Finisher PWB. Execute dc330 Component Control [012-263], Stacker Encoder Sensor. Manually rotate the Encoder (PL 23.7) to block and unblock the sensor. The display changes. Y↓ N→Check the wire between J8874 pin 2 and P/J8988 pin 23 for an open or short circuit, or a loose or damaged connector. The wire is OK. Y↓ N→Repair/reconnect as required. Measure the voltage between P/J8988, pins 22 and 24 on the Finisher PWB (Stacker Tray Control). The voltage is approx. +5VDC. Y↓ N→Replace the Finisher PWB. Measure the voltage between P/J8988, pin 23 on the Finisher PWB and GND (Stacker Tray Control). Manually rotate the Encoder (PL 23.7) to block and unblock the Stacker Encoder Sensor. The voltage changes. Y↓ N→Replace the Stacker Encoder Sensor (PL 23.7). Replace the Finisher PWB. Alternately execute dc330 Component Control [012-060], Stacker Motor Up, and [012-061], Stacker Motor Down. The Stacker Motor (PL 23.7) Moves. Y↓ N→There is +24 VDC from P/J8986 pin 12 to GND (Stacker Tray Control) Y↓ N→Go to Finisher Interlock Switching and check the circuit of the Option Switch (PL 23.9). Repair/reconnect as required. Check the wires between P/J8986 pins 11 and 12, and the Stacker Motor for an open or short circuit, or a loose or damaged connector. The wires are OK. Y↓ N→Repair/reconnect as required. Replace the Stacker Elevator Motor. If the problem persists, replace the Finisher PWB. Replace the Finisher PWB.
Execute dc330 Component Control [012-264], Stacker Height Sensor 1. Actuate the Stacker Height Sensor 1. The display changes. Y↓ N→Check the wire between J8873 pin 2 and P/J8988 pin 17 for an open or short circuit, or a loose or damaged connector. The wire is OK. Y↓ N→Repair/reconnect as required. Measure the voltage between P/J8988, pins 16 and 18 on the Finisher PWB (Stacker Tray Control). The voltage is approx. +5VDC. Y↓ N→Replace the Finisher PWB. Measure the voltage between P/J8988, pin 17 on the Finisher PWB and GND (Stacker Tray Control). Actuate the Stacker Height Sensor 1. The voltage changes. Y↓ N→Replace the Stacker Height Sensor 1. Replace the Finisher PWB. Execute dc330 Component Control [012-263], Stacker Encoder Sensor. Manually rotate the Encoder (PL 23.7) to block and unblock the sensor. The display changes. Y↓ N→Check the wire between J8874 pin 2 and P/J8988 pin 23 for an open or short circuit, or a loose or damaged connector. The wire is OK. Y↓ N→Repair/reconnect as required. Measure the voltage between P/J8988, pins 22 and 24 on the Finisher PWB (Stacker Tray Control). The voltage is approx. +5VDC. Y↓ N→Replace the Finisher PWB. Measure the voltage between P/J8988, pin 23 on the Finisher PWB and GND (Stacker Tray Control). Manually rotate the Encoder (PL 23.7) to block and unblock the Stacker Encoder Sensor. The voltage changes. Y↓ N→Replace the Stacker Encoder Sensor (PL 23.7). Replace the Finisher PWB. Alternately execute dc330 Component Control [012-060], Stacker Motor Up, and [012-061], Stacker Motor Down. The Stacker Motor (PL 23.7) Moves. Y↓ N→There is +24 VDC from P/J8986 pin 12 to GND (Stacker Tray Control) Y↓ N→Go to Finisher Interlock Switching and check the circuit of the Option Switch (PL 23.9). Repair/reconnect as required. Check the wires between P/J8986 pins 11 and 12, and the Stacker Motor for an open or short circuit, or a loose or damaged connector. The wires are OK. Y↓ N→Repair/reconnect as required. Replace the Stacker Elevator Motor. If the problem persists, replace the Finisher PWB. Replace the Finisher PWB.