Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 312.213 — Xerox Phaser 7800

Code: 312.213

Description: Stacker Lower Limit Fault. When Lower Limit Sensor On was detected after the Stacker Tray had started driving down.
Remedy: • The Upper Limit SW for improper installation • The Upper Limit SW connectors for connection failure • The Elevator Motor for operation failure • The Elevator Motor connectors for connection failure
Enter dc330 Component Control [012-061] Elevator Motor Down and [012-060] Elevator Motor Up (PL 24.31 Item 26), alternately. Select Start. The Elevator Motor runs. Y↓ N→Select Stop. Go to Finisher Stacker Drive. Check continuity between the Elevator Motor and Finisher PWB. The continuity check is OK. Y↓ N→Repair the open circuit or short circuit. Replace the Elevator Motor. If the problem continues, replace the Finisher Main PWB. Select Stop. If the problem continues, replace the Finisher Main PWB.