Description: Front Tamper Home Sensor On Fault. After the Front Tamper started moving to the home position, the Front Tamper Home Sensor did not turn On within 800ms.
Remedy: Manually operate the Tamper mechanism. The Tamper mechanism moves smoothly. Y↓ N→Replace the parts that are interfering with operation. Execute dc330 Component Control [012-220], Front Tamper Home Sensor. Manually operate the Tamper mechanism to block and unblock the sensor. The display changes. Y↓ N→Check the wire between J8881 pin 2 and J8984 pin 5 for an open or short circuit, or a loose or damaged connector. The wire is OK. Y↓ N→Repair/reconnect as required. Measure the voltage between J8984, pins 6 and 4 on the Finisher PWB (Tamping Control (2 of 2)). The voltage is approx. +5VDC. Y↓ N→Replace the Finisher PWB. Measure the voltage between J8984, pin 5 on the Finisher PWB and GND (Tamping Control (2 of 2)). Manually operate the Tamper mechanism to block and unblock the Front Tamper Home Sensor. The voltage changes. Y↓ N→Replace the Front Tamper Home Sensor. Replace the Finisher PWB. Alternately execute dc330 Component Control [012-020], Front Tamper Motor Front and [012- 023], Front Tamper Motor Rear. The Front Tamper Motor moves. Y↓ N→There is +24 VDC from J8984 pin 19 on the Finisher PWB to GND Y↓ N→There is +24 VDC from J8982 pin 4 on the Finisher PWB to GND Y↓ N→Go to Finisher Interlock Switching and check the +24V circuit feeding pin 4. Repair/reconnect as required. Replace the Finisher PWB. Check the wires between J8984, pins 18 ~ 22 on the Finisher PWB, and the Front Tamper Motor J8984 for an open or short circuit, or a loose or damaged connector. The wires are OK. Repair/reconnect as required. Replace the front Tamper Motor. If the problem persists, replace the Finisher PWB. Replace the Finisher PWB.