Code: 312.260
Description: Eject Clamp Home Sensor On Fault. After the Eject Clamp started ascending, the Eject Clamp Home Sensor did not turn On within 500ms.
Remedy: • Manually operate the Eject mechanism. Check for binding, a dirty sensor, or damage. • Check the actuator for the Eject Clamp Home Sensor b for damage
Execute dc330 Component Control [012-250], Eject Clamp Home Sensor. Block and unblock the Eject Clamp Home Sensor The display changes. Y↓ N→Check the wire between J8870 pin 2 on the Eject Clamp Home Sensor and P/J8988 pin 8 on the Finisher PWB for an open or short circuit, or loose or damaged connectors. The wire is OK. Y↓ N→Repair/replace as required. Measure the voltage between P/J8988, pins 9 and 7 on the Finisher PWB. The voltage is approx. +5VDC. Y↓ N→Replace the Finisher PWB. Measure the voltage between P/J8988 pin 8 on the Finisher PWB and GND. Actuate the Eject Clamp Home Sensor. The voltage changes. Y↓ N→Replace the Eject Clamp Home Sensor. Replace the Finisher PWB. Alternately execute dc330 Component Control [012-052], Eject Clamp Up and [012-053], Eject Clamp Down. The Eject Motor (PL 23.11) starts up. Y↓ N→Check the wires between P/J8878 pins 1~6 on the Eject Motor and P/J8983 pins 5~8 on the Finisher PWB for an open or short circuit, or loose or damaged connectors (Set Eject Control (1 of 2)). The wires are OK. Y↓ N→Repair/replace as required. Measure the resistance of the Eject Motor between each pin of P/J8878-1/3/4/6. The resistance is approx. 2Ohm. Y↓ N→Replace the Eject Motor. Replace the Finisher PWB. If the problem remains, replace the Eject Motor Go to Set Eject Control (1 of 2). Check for an intermittent circuit or intermittent mechanical problem. If the check is OK, replace the Finisher PWB.
Execute dc330 Component Control [012-250], Eject Clamp Home Sensor. Block and unblock the Eject Clamp Home Sensor The display changes. Y↓ N→Check the wire between J8870 pin 2 on the Eject Clamp Home Sensor and P/J8988 pin 8 on the Finisher PWB for an open or short circuit, or loose or damaged connectors. The wire is OK. Y↓ N→Repair/replace as required. Measure the voltage between P/J8988, pins 9 and 7 on the Finisher PWB. The voltage is approx. +5VDC. Y↓ N→Replace the Finisher PWB. Measure the voltage between P/J8988 pin 8 on the Finisher PWB and GND. Actuate the Eject Clamp Home Sensor. The voltage changes. Y↓ N→Replace the Eject Clamp Home Sensor. Replace the Finisher PWB. Alternately execute dc330 Component Control [012-052], Eject Clamp Up and [012-053], Eject Clamp Down. The Eject Motor (PL 23.11) starts up. Y↓ N→Check the wires between P/J8878 pins 1~6 on the Eject Motor and P/J8983 pins 5~8 on the Finisher PWB for an open or short circuit, or loose or damaged connectors (Set Eject Control (1 of 2)). The wires are OK. Y↓ N→Repair/replace as required. Measure the resistance of the Eject Motor between each pin of P/J8878-1/3/4/6. The resistance is approx. 2Ohm. Y↓ N→Replace the Eject Motor. Replace the Finisher PWB. If the problem remains, replace the Eject Motor Go to Set Eject Control (1 of 2). Check for an intermittent circuit or intermittent mechanical problem. If the check is OK, replace the Finisher PWB.