Code: 312.295
Description: Stapler Move Position Sensor On Fault. Stapler Move Position Sensor is not turned On within a specified time. Stapler Move Position Sensor not turned On when home operation is completed. Stapler Move Position Sensor is not turned On after the stop following Stapler Move Position Sensor On.
Remedy: • Check Actuator for deformation • Check Stapler Move Position Sensor for improper installation • Check Stapler Move Position Sensor connectors for connection failure • Check Staple Move Motor connectors for connection failure • Check Staple Guide for deformation
Enter dc330 Component Control [012-046] and [012-047], Stapler Move Motor (PL 24.33 Item 9), alternately. Select Start. The Staple Move Motor energizes. Y↓ N→Select Stop. Go to Finisher Staple Positioning. Check continuity between the Stapler Move Motor and Finisher PWB. The continuity check is OK. Y↓ N→Repair the open circuit or short circuit. Replace the Staple Move Motor (PL 24.33 Item 9). If the problem continues, replace the Finisher Main PWB. Select Stop. Select dc330 Component Control [012-241], Stapler Move Position Sensor (PL 24.33 Item 5). Select Start. Block/unblock the Stapler Move Position Sensor. The display changed. Y↓ N→Select Stop. Go to Finisher Staple Positioning. Check continuity between the Stapler Move Position Sensor and Finisher PWB. The continuity check is OK. Y↓ N→Repair the open circuit or short circuit. Replace the Stapler Move Position Sensor (PL 24.33 Item 5). If the problem continues, replace the Finisher Main PWB. Select Stop. Check the following: • Obstructions on the Stapler Upper Rail • Stapler Move Motor Gear If the above checks are OK. replace the Finisher Main PWB.
Enter dc330 Component Control [012-046] and [012-047], Stapler Move Motor (PL 24.33 Item 9), alternately. Select Start. The Staple Move Motor energizes. Y↓ N→Select Stop. Go to Finisher Staple Positioning. Check continuity between the Stapler Move Motor and Finisher PWB. The continuity check is OK. Y↓ N→Repair the open circuit or short circuit. Replace the Staple Move Motor (PL 24.33 Item 9). If the problem continues, replace the Finisher Main PWB. Select Stop. Select dc330 Component Control [012-241], Stapler Move Position Sensor (PL 24.33 Item 5). Select Start. Block/unblock the Stapler Move Position Sensor. The display changed. Y↓ N→Select Stop. Go to Finisher Staple Positioning. Check continuity between the Stapler Move Position Sensor and Finisher PWB. The continuity check is OK. Y↓ N→Repair the open circuit or short circuit. Replace the Stapler Move Position Sensor (PL 24.33 Item 5). If the problem continues, replace the Finisher Main PWB. Select Stop. Check the following: • Obstructions on the Stapler Upper Rail • Stapler Move Motor Gear If the above checks are OK. replace the Finisher Main PWB.