Description: H-Transport Cover Open. H-Transport Interlock Sensor-L Open was detected.
Remedy: • The H-Transport Interlock Sensor-L for improper installation • Check for obstruction in between the H-Transport Cover and the H-Transport paper transport area • The H-Transport Cover Interlock Sensor connectors for connection failure • The Actuator for deformation Select Start. Block and unblock the H-Transport Interlock Sensor-L. The display changes. Y↓ N→+5 VDC is measured between the H-Transport Interlock Sensor P/J8445--1 and -3. Y↓ N→Go to Finisher Horizontal Transportation (2 of 2). Disconnect J8310 on Finisher PWB. +5 VDC is measured between H Transport Interlock Sensor P/ P/ J8445-1 and -3. Y↓ N→Replace the H-Transport PWB (PL 24.44 Item 19). Check for an open circuit between H-Transport PWB P/J8396-3 and -1 and H-Transport Interlock Sensor P/J8445-1 and -3. +5 VDC is measured between Finisher PWB J8310-20 and ground. Y↓ N→Replace the Finisher Main PWB +5 VDC is measured at the H-Transport Interlock Sensor J8445-2 and ground. Y↓ N→Check for an open circuit between H-Transport Interlock Switch P/J8445-1 and HTransport Interlock Sensor P/J8445-2. Replace the H-Transport Interlock Sensor. Select Stop. Check the following: • Alignment between the H-Transport Cover and the H-Transport Interlock Sensor • The H-Transport Cover for proper installation • The Actuator for bending or alignment • The Magnets for proper mounting