Description: IOT Center Tray Full. The H-Transport Entrance Sensor is detected to be On for 10 successive seconds.
Remedy: Check the H-Transport Drive Rolls (PL 23.4) and Pinch Rolls (PL 23.3 Item 8) for wear or contamination. Check for obstructions or damage in the paper path. The Rolls and Paper Path are OK. Y↓ N→Clean or replace as required. Execute dc330 Component Control [012-190], H-Transport Entrance Sensor. Actuate the HTransport Entrance Sensor (PL 23.4 Item 6). The display changes. Y↓ N→Check the wire between P/J8861 pin 2 and J8987 pin 6 for an open or short circuit, or a loose or damaged connector. The wire is OK. Y↓ N→Repair/reconnect as required. Measure the voltage between J8987, pins 4 and 5 on the Finisher PWB (Horizontal Paper Transportation). The voltage is approx. +5VDC. Y↓ N→Replace the Finisher PWB. Measure the voltage between J8987, pin 6 on the Finisher PWB and GND (Horizontal Paper Transportation). Actuate the H-Transport Entrance Sensor. The voltage changes. Y↓ N→Replace the H-Transport Entrance Sensor (PL 23.4 Item 6). Replace the Finisher PWB. Power Off. Open the H-Transport Top Cover. Cheat the H-Transport Interlock Sensor. Power On. The H-Transport Belt rotates. Y↓ N→Check the wires between P/J8862 on the H-Transport Motor and J8987 on the Finisher PWB for an open or short circuit, or a loose or damaged connector. The wires are OK. Y↓ N→Repair/reconnect as required. Measure the resistance of the H-Transport Motor between each pin J8862-1/2/5/6 (Horizontal Paper Transportation). The resistance is approx. 20 Ohm. Y↓ N→Replace the H-Transport Motor. Replace the Finisher PWB. If the problem persists, replace the H-Transport Motor. Check the H-Transport Entrance Sensor and H-Transport Motor circuits for an intermittent condition. If the problem continues, replace the Finisher PWB.