Remedy: Procedure Execute dc330 Component Control [013-143], Booklet Staple Move Home Sensor. Move the Booklet Staplers to block and unblock the Sensor (PL 23.18 Item 13). The display changes. Y↓ N→Check the wire between J8897 pin 2 and P/J8991 pin 2 for an open or short circuit, or a loose or damaged connector. The wire is OK. Y↓ N→Repair/reconnect as required. Measure the voltage between P/J8991, pins 3 and 1 on the Booklet PWB (Booklet Staple Positioning). The voltage is approx. +5VDC. Y↓ N→Replace the Booklet PWB. Measure the voltage between P/J8991 pin 2 on the Booklet PWB and GND (Booklet Staple Positioning). Actuate the Booklet Staple Move Home Sensor. The voltage changes. Y↓ N→Replace the Booklet Staple Move Home Sensor (PL 23.18 Item 13). Replace the Booklet PWB. Alternately execute dc330 Component Control [013-028], Stapler Move Motor In and [013- 029], Stapler Move Motor Out. The Stapler Move Motor moves. Y↓ N→Check the wires between P/J8992 pins 1~6 on the Booklet PWB and P/J8906 on the Booklet Stapler Move Motor (Booklet Staple Positioning) for an open or short circuit, or loose or damaged connectors. The wires are OK. Y↓ N→Repair/replace as required. Monitor the voltage at P/J8994, pin 3 (Booklet Staple Positioning). Alternately execute dc330 Component Control [013-028], Stapler Move Motor In and [013-029], Stapler Move Motor Out. An AC clock pulse is detected. Y↓ N→Check the wire between P/J8994, pin 3 and P/J8995 pin 4. If the wire is OK, replace the Finisher PWB. Replace the Booklet Stapler Move Motor. If the problem persists, replace the Booklet PWB. Go to Booklet Staple Positioning and check for an intermittent circuit.