Description: Booklet Staple Move Position Sensor On Fault
Remedy: Execute dc330 Component Control [013-144], Booklet Staple Move Position Sensor. Move the Booklet Stapler to block and unblock the Sensor (PL 23.18 Item 13). The display changes. Y↓ N→Check the wire between J8898 pin 2 and P/J8991 pin 5; and the wire between J8894, pin 5 and P/J8995 pin 5 for an open or short circuit, or a loose or damaged connector. The wires are OK. Y↓ N→Repair/reconnect as required. Measure the voltage between P/J8991, pins 6 and 4 on the Booklet PWB (Booklet Staple Positioning). The voltage is approx. +5VDC. Y↓ N→Replace the Booklet PWB. Measure the voltage between P/J8991 pin 5 on the Booklet PWB and GND (Booklet Staple Positioning). Actuate the Booklet Staple Move Position Sensor. The voltage changes. Y↓ N→Replace the Booklet Staple Move Position Sensor (PL 23.18 Item 13). Measure the voltage between J8985 pin 5 on the Finisher PWB and GND (Booklet Staple Positioning). Actuate the Booklet Staple Move Position Sensor. The voltage changes. Y↓ N→Replace the Booklet PWB. If the problem persists, replace the Finisher PWB. Replace the Finisher PWB. Alternately execute dc330 Component Control [013-028], Stapler Move Motor In and [013- 029], Stapler Move Motor Out. The Stapler Move Motor moves. Y↓ N→Check the wires between P/J8992 pins 1~6 on the Booklet PWB and P/J8906 on the Booklet Stapler Move Motor (Booklet Staple Positioning) for an open or short circuit, or loose or damaged connectors. The wires are OK. Y↓ N→Repair/replace as required. Monitor the voltage at J8894, pin 3 (Booklet Staple Positioning). Alternately execute dc330 Component Control [013-028], Stapler Move Motor In and [013-029], Stapler Move Motor Out. An AC clock pulse is detected. Y↓ N→Check the wire between J8894, pin 3 and P/J8995 pin 4. If the wire is OK, replace the Finisher PWB. Replace the Booklet Stapler Move Motor. If the problem persists, replace the Booklet PWB. Go to Booklet Staple Positioning and check for an intermittent circuit.