Code: 342.320
Description: Drum Y, M, C Motor Fail. The Drum Drive Motor (Y, M, C) revolution failure was detected.
Remedy: Turn the power Off and open the Front Cover. Remove the Drum (Y, M, C) and close the Front Cover. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [091-027] (Drum Drive Motor Y, M, C). Does the Drum Drive Motor (Y, M, C) rotate? Y↓ N→Turn the power Off and remove the Rear Upper Cover. Turn the power ON. Is the voltage between the MD PWB P/J526-3 (+) and the GND (-) +24VDC? Y↓ N→Go to +24VDC Power RAP. Is the voltage between the MD PWB P/J527-A16 (+) and the GND (-) +5VDC? Y↓ N→Go to +5VDC Power RAP. Turn the power Off and check the connections between the MD PWB P/J526 and the Drum Drive Motor (Y, M, C) P/J246, as well as between the MD PWB P/J527 and the Drum Drive Motor (Y, M, C) P/J247 for open circuits, short circuits, and poor contacts. If no problems are found, replace the following parts in sequence: • Drum Drive Motor (Y, M, C) • MD PWB • MCU PWB Press the Stop button and open the Front Cover. Install the Drum (Y, M, C) and close the Front Cover. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [091-027] (Drum Drive Motor Y, M, C). Does the Drum Drive Motor (Y, M, C) rotate? Y↓ N→Check the Drum (Y, M, C) for loading. Press the Stop button and turn the power Off. Check the connection between the Drum Drive Motor (Y, M, C) P/J247-8 and the MD PWB P/J527-A9 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • MD PWB • MCU PWB