Description: IBT Motor Fail. The IBT Drive Motor revolution failure was detected.
Remedy: Turn the power Off. Remove the IBT Unit and cheat the L/H Cover Interlock Switch. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [094-006] (IBT Drive Motor). Does the IBT Drive Motor rotate? Y↓ N→Turn the power Off and remove the Rear Upper Cover. Turn the power On. Is the voltage between the MD PWB P/J526-5 (+) and the GND (-) +24VDC? Y↓ N→Go to +24VDC Power RAP. Is the voltage between the MD PWB P/J527-B8 (+) and the GND (-) +5VDC? Y↓ N→Go to +5VDC Power RAP. Turn the power Off and check the connections between the MD PWB P/J526 and the IBT Drive Motor P/J248, as well as between the MD PWB P/J527 and the IBT Drive Motor P/ J249 for open circuits, short circuits, and poor contacts. If no problems are found, replace the following parts in sequence: • IBT Drive Motor • MD PWB • MCU PWB Press the Stop button and turn the power Off. Install the IBT Unit and close the L/H Cover. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [094-006] (IBT Drive Motor). Does the IBT Drive Motor rotate? Y↓ N→Check the IBT Drive for loading. Also, check the IBT for loading due to blockage in the IBT Waste Toner Collection Auger Press the Stop button and turn the power Off. Check the connection between the IBT Drive Motor P/J249-8 and the MD PWB P/J527-B1 for open circuit, short circuit, and poor contact. If no problems are found, replace the MD PWB.