Mã lỗi 342.330 — Xerox Phaser 7800

Code: 342.330

Description: IH Exhaust Fan Fail. The IH Exhaust Fan error was detected.
Remedy: Enter dc122 Fault History. Has 341.326/ 341.331 faults (MCU PWB F3 Open) occurred? Y↓ N→Turn the power Off and remove the Rear Upper Cover. Disconnect the connector P592 of the MD PWB and open the Chassis Assembly. Rotate the IH Exhaust Fan manually to check for loading. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [042-025] (NOHAD FAN Failure Detection). Is the IH Exhaust Fan rotating and does the test return an IH Exhaust Fan error? Y↓ N→When the Diag is turned On, is the voltage between the MCU PWB P/J414-B1 (+) and the GND (-) +24VDC? Y↓ N→Turn the power Off and replace the MCU PWB. Turn the power Off and check the connection between the IH Exhaust Fan P/J225 and the MCU PWB P/J414 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • IH Exhaust Fan • MCU PWB Replace the IH Exhaust Fan. Press the Stop button and turn the power Off. Check the connection between the IH Exhaust Fan P/J225-3 and the MCU PWB P/J414-B3 for open circuit, short circuit, and poor contact. If no problems are found, replace the MCU PWB. Go to the 341.326/ 341.331 RAP.