Mã lỗi 342.334 — Xerox Phaser 7800

Code: 342.334

Description: IBT Fan Fail. The IBT Fan 1, 2 error was detected.
Remedy: Enter dc122 Fault History. Has 341.327/ 341.332 faults (MCU PWB F4 Open) occurred? Y↓ N→Turn the power Off and remove the Rear Upper Cover. Open the Front Cover and cheat the Front Cover Interlock Switch. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [042-019] (IBT Fan). Does the IBT Fan1, 2 rotate? Y↓ N→When the Diag is turned On, is the voltage between the MCU PWB P/J416-3/7 (+) and the GND (-) +24VDC? Y↓ N→Turn the power Off and replace the MCU PWB. Turn the power Off and check the connection between the IBT Fan 1 J232 and the MCU PWB P/J416, as well as between the IBT Fan 2 P/J236 and the MCU PWB P/ J416 for open circuits, short circuits, and poor contacts. If no problems are found, replace the following parts in sequence: • IBT Fan 1 • IBT Fan 2 • MCU PWB Press the Stop button and turn the power Off. Check the connection between the IBT Fan 1 J232-2 and the MCU PWB P/J416-5, as well as between the IBT Fan 2 P/J236-2 and the MCU PWB P/J416-9 for open circuits, short circuits, and poor contacts. If no problems are found, replace the MCU PWB. Go to the 341.327/ 341.332 RAP.

← Xem tất cả mã lỗi Xerox Phaser 7800