Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 342.335 — Xerox Phaser 7800

Code: 342.335

Description: Process 1 Fan Fail. The Process 1 Fan error was detected.
Remedy: Enter dc122 Fault History. Has 341.350 faults (MD PWB F7 Open) occurred? Y↓ N→Turn the power Off and remove the Rear Upper Cover. Open the Front Cover and cheat the Front Cover Interlock Switch. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [042-025] (NOHAD FAN Failure Detection). Is the Process 1 Fan rotating and does the test return a Process 1 Fan error? Y↓ N→When the Diag is turned On, is the voltage between the MD PWB P/J537-1 (+) and the GND (-) +24VDC? Y↓ N→Turn the power Off and replace the MD PWB. Turn the power Off and check the connection between the Process 1 Fan P/J228 and the MD PWB P/J537 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • Process 1 Fan • MD PWB Replace the Process 1 Fan. Press the Stop button and turn the power Off. Check the connection between the Process 1 Fan P/J228-2 and the MD PWB P/J537-3 for open circuit, short circuit, and poor contact. If no problems are found, replace the MD PWB. Go to the 341.350 RAP.