Mã lỗi 342.338 — Xerox Phaser 7800

Code: 342.338

Description: LVPS Front Fan Fail. An abnormality was detected in the LVPS Front Fan.
Remedy: Enter dc122 Fault History. Has 341.350 faults (MD PWB F7 Open) occurred? Y↓ N→Turn the power Off and remove the Right Cover and Rear Upper Cover. Disconnect and reconnect P/J239. Rotate the Front LVPS Fan manually to check for loading. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [042-025] (NOHAD FAN Failure Detection). Is the Front LVPS Fan rotating and does the test return a LVPS Front Fan error? Y↓ N→When the Diag is turned On, is the voltage between the MD PWB P/J529-A13 (+) and the GND (-) +24VDC? Y↓ N→Turn the power Off and replace the MD PWB. Turn the power Off and check the connection between the Front LVPS Fan P/J239 and the MD PWB P/J529 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • Front LVPS Fan • MD PWB Replace the Front LVPS Fan. Press the Stop button and turn the power Off. Check the connection between the Front LVPS Fan P/J239-2 and the MD PWB P/J529-A14 for open circuit, short circuit, and poor contact. If no problems are found, replace the MD PWB. Go to the 341.350 RAP.