Mã lỗi 342.341 — Xerox Phaser 7800

Code: 342.341

Description: M HVPS Fan Fail. The M Fan error was detected.
Remedy: Enter dc122 Fault History. Has 341.325/ 341.330 faults (MCU PWB F2 Open) occurred? Y↓ N→Turn the power Off and remove the Rear Upper Cover. Disconnect the connector P592 of the MD PWB and open the Chassis Assembly. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [042-025] (NOHAD FAN Failure Detection). Is the HVPS Fan or the M Fan rotating and does the test return a M HVPS Fan error? Y↓ N→When the Diag is turned On, is the voltage between the MCU PWB P/J417-A10 (+) and the GND (-) +24VDC? Y↓ N→Turn the power Off and replace the MCU PWB. Turn the power Off and check the connection between the HVPS/M Fan P/J235 and the MCU PWB P/J417 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • M HVPS Fan • MCU PWB Replace the H HVPS Fan. Press the Stop button and turn the power Off. Check the connection between the HVPS/M Fan P/J235-3 and the MCU PWB P/J417- A12 for open circuit, short circuit, and poor contact. If no problems are found, replace the MCU PWB. Go to the 341.325/ 341.330 RAP.