Mã lỗi 342.343 — Xerox Phaser 7800

Code: 342.343

Description: Rear Bottom Fan Fail. The Bottom Fan error was detected.
Remedy: Enter dc122 Fault History. Has 341.325/ 341.330 faults (MCU PWB F2 Open) occurred? Y↓ N→Turn the power Off and remove the Rear Upper Cover. Disconnect the connector P592 of the MD PWB and open the Chassis Assembly. Rotate the Bottom Fan manually to check for loading. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [042-025] (NOHAD FAN Failure Detection). Is the Bottom Fan rotating and does the test return a Rear Bottom Fan error? Y↓ N→When the Diag is turned On, is the voltage between the MCU PWB P/J417-B11 (+) and the GND (-) +24VDC? Y↓ N→Turn the power Off and replace the MCU PWB. Turn the power Off and check the connection between the Bottom Fan P/J234 and the MCU PWB P/J417 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • Bottom Fan • MCU PWB Replace the Bottom Fan. Press the Stop button and turn the power Off. Check the connection between the Bottom Fan P/J234-2 and the MCU PWB P/J417-B13 for open circuit, short circuit, and poor contact. If no problems are found, replace the MCU PWB. Go to the 341.325/ 341.330 RAP.

← Xem tất cả mã lỗi Xerox Phaser 7800