Mã lỗi 342.609 — Xerox Phaser 7800

Code: 342.609

Description: LH Fan Fail. The LH Fan 1-3 error was detected.
Remedy: Enter dc122 Fault History. Has 041-355 faults (MD PWB F10 Open) occurred? Y↓ N→Turn the power Off. Open the L/H Cover and cheat the L/H Cover Interlock Switch. Disconnect and reconnect the LH Fan PWB P/J453, P/J454, LH Fan 2 P/J217, and LH Fan 3 P/J218. Rotate the LH Fan 1-3 manually to check for loading. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [042-025] (NOHAD FAN Failure Detection). Are the LH Fan 1-3 rotating and does the test return a LH 1, 2, 3 Fan error? Y↓ N→Press the Stop button. Is the voltage between the LH Fan PWB J450-5 (+) and the GND (-) +24VDC? Y↓ N→Remove the Rear Upper Cover. Is the voltage between the MD PWB J523- B13 (+) and the GND (-) +24VDC? Y↓ N→Turn the power Off and replace the MD PWB. Turn the power Off and check the connection between the MD PWB P/J523 and the LH Fan PWB P/J450 for open circuit, short circuit, and poor contact. Turn On dc330 Component Control [042-026] (LH Fan) and measure the following voltages: • Between the LH Fan PWB P/J453-1 (+) and the GND (-) (LH Fan 1) • Between the LH Fan PWB P/J454-1 (+) and the GND (-) (LH Fan 2) • Between the LH Fan PWB P/J454-5 (+) and the GND (-) (LH Fan 3) Is the voltage +24VDC? Y↓ N→Turn the power Off and check the connection between the MD PWB P/J523 and the LH Fan PWB P/J450 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • LH Fan PWB • MD PWB • MCU PWB Press the Stop button and turn the power Off Check the following connectors for open circuits, short circuits, and poor contacts. • Between the LH Fan PWB P/J454 and the LH Fan 2 P/J217 • Between the LH Fan PWB P/J454 and the LH Fan 3 P/J218 If no problems are found, replace the appropriate LH Fan (1-3). Replace the LH Fan. Press the Stop button. Turn the power Off and check the following: • Check the connection between the LH Fan 2 P/J217-3 and the LH Fan PWB P/ J454-3 for open circuit, short circuit, and poor contact. • Check the connection between the LH Fan 3 P/J218-3 and the LH Fan PWB P/ J4544-7 for open circuit, short circuit, and poor contact. • Check the connection between the LH Fan PWB P/J450-2 and the MD PWB P/ J523-B16 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • LH Fan PWB • MD PWB Go to the 341.355 RAP.

← Xem tất cả mã lỗi Xerox Phaser 7800

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie