Code: 342.609
Description: LH Fan Fail. The LH Fan 1-3 error was detected.
Remedy: Enter dc122 Fault History. Has 041-355 faults (MD PWB F10 Open) occurred? Y↓ N→Turn the power Off. Open the L/H Cover and cheat the L/H Cover Interlock Switch. Disconnect and reconnect the LH Fan PWB P/J453, P/J454, LH Fan 2 P/J217, and LH Fan 3 P/J218. Rotate the LH Fan 1-3 manually to check for loading. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [042-025] (NOHAD FAN Failure Detection). Are the LH Fan 1-3 rotating and does the test return a LH 1, 2, 3 Fan error? Y↓ N→Press the Stop button. Is the voltage between the LH Fan PWB J450-5 (+) and the GND (-) +24VDC? Y↓ N→Remove the Rear Upper Cover. Is the voltage between the MD PWB J523- B13 (+) and the GND (-) +24VDC? Y↓ N→Turn the power Off and replace the MD PWB. Turn the power Off and check the connection between the MD PWB P/J523 and the LH Fan PWB P/J450 for open circuit, short circuit, and poor contact. Turn On dc330 Component Control [042-026] (LH Fan) and measure the following voltages: • Between the LH Fan PWB P/J453-1 (+) and the GND (-) (LH Fan 1) • Between the LH Fan PWB P/J454-1 (+) and the GND (-) (LH Fan 2) • Between the LH Fan PWB P/J454-5 (+) and the GND (-) (LH Fan 3) Is the voltage +24VDC? Y↓ N→Turn the power Off and check the connection between the MD PWB P/J523 and the LH Fan PWB P/J450 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • LH Fan PWB • MD PWB • MCU PWB Press the Stop button and turn the power Off Check the following connectors for open circuits, short circuits, and poor contacts. • Between the LH Fan PWB P/J454 and the LH Fan 2 P/J217 • Between the LH Fan PWB P/J454 and the LH Fan 3 P/J218 If no problems are found, replace the appropriate LH Fan (1-3). Replace the LH Fan. Press the Stop button. Turn the power Off and check the following: • Check the connection between the LH Fan 2 P/J217-3 and the LH Fan PWB P/ J454-3 for open circuit, short circuit, and poor contact. • Check the connection between the LH Fan 3 P/J218-3 and the LH Fan PWB P/ J4544-7 for open circuit, short circuit, and poor contact. • Check the connection between the LH Fan PWB P/J450-2 and the MD PWB P/ J523-B16 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • LH Fan PWB • MD PWB Go to the 341.355 RAP.