Description: LPH Act Fault Multi. Communication error between MCU and multiple LPH Units (error in the communication IC or cable).
Remedy: Turn the power Off and remove the Rear Upper Cover. Turn the power On. Check the timing at when this Fail occurs. Does this Fail occur right after the power is turned ON? Y↓ N→If the Fail occurs when the Drum is rotating, it is very likely due to the noise caused by high voltage leak. Check the Drum (Y, M, C, K) for improper installation Is the voltage between the MD PWB P/J532-4/8/12/16 (+) and the GND (-) +5VDC? Y↓ N→Go to +5VDC Power RAP. Is the voltage between the MD PWB P/J532-2/6/10/14 (+) and the GND (-) +1.8VDC? Y↓ N→Turn the power Off and disconnect the MD PWB connector P/J532. Measure the resistance between the MD PWB P/J532-2/6/10/14 and the Frame. Is the resistance infinite for all? Y↓ N→Check the wires of the pins with non-infinite resistance for peeled-off coatings and short circuits due to pinching. Replace the MD PWB. Turn the power Off and check the following connectors for open circuit, short circuit, and poor connection. • Between MCU PWB P/J557 and LPH Rear PWB P/J561 • Between MCU PWB P/J556 and LPH Rear PWB P/J560 • Between MCU PWB P/J555 and LPH Rear PWB P/J559 • Between MCU PWB P/J554 and LPH Rear PWB P/J558 If no problems are found, replace the MCU PWB. If the problem persists, refer to dc131 NVM Read/Write [749-001] (LPH Fail Color) to go to the appropriate RAP. (1: Error has occurred at Y, 2: Error has occurred at M, 4: Error has occurred at C, 8: Error has occurred at K) • Y color: 361.370 RAP