Description: Exit 2 OCT Home Fault. After the Exit 2 OCT Motor has ran for the specified operation time, the Exit 2 OCT Home Position Sensor does not turn On.
Remedy: • Check the Exit 2 OCT Home Position Sensor for improper installation, contamination, and etc. • Check the Shielding Board, which blocks the detection section of the Exit 2 OCT Home Position Sensor, for damage and check the OCT 2 Chute for improper installation. Turn the power On and enter Service Diagnostics (Entering Service Diagnostics). Turn On dc330 Component Control [077-110]. Move the OCT 2 Chute manually to block/clear the light path to the Exit 2 OCT Home Position Sensor. Does the display change between High/Low? Y↓ N→Use Transmissive Sensor RAP to check the Exit 2 OCT Home Position Sensor. Press the Stop button. Turn On dc330 Component Control [077-045] and dc330 Component Control [077-046] alternately. Does the OCT 2 Chute move forward and backward? Y↓ N→Is the voltage between the MD PWB P/J522-A3/A4 (+) and the GND (-) +24VDC? Y↓ N→Go to +24VDC Power RAP. Turn the power Off and check the Exit 2 OCT Motor Gear for blockage and the OCT 2 Chute for damage. Also, check the connection between the MD PWB P/J522 and the Exit 2 OCT Motor P/J266 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • Exit 2 OCT Motor (PL 17.5 Item 11) • MD PWB Press the Stop button and turn the power Off. Replace the MD PWB.