Description: Tray 1 Nudger Up Down Fault. The Tray 1 Nudger Position Sensor does not change within the specified time after the Tray 1 Nudger Up or Down operation has started.
Remedy: Turn the power On and enter Service Diag mode (Entering Service Diagnostics). Turn On dc330 Component Control [075-002] (Tray 1 Feed/Nudger Motor). Does the Tray 5 Feed/ Nudger Motor rotate? Y↓ N→Is the voltage between the MD PWB P/J520-1 (+) and the GND (-) +24VDC? Y↓ N→Go to +24VDC Power RAP. Turn the power Off, then measure the Tray 1 Feed/Nudger Motor wire wound resistance. Check the resistance of the following. • Between the MD PWB P/J525-B10 and the P/J525-B11 • Between the MD PWB P/J525-B12 and the P/J525-B13 Is the resistance approx. 4.0 Ohm for each? (At 25° C / 77° F) Y↓ N→Check the connection between the MD PWB P/J525 and Tray 1 Feed/Nudger Motor P/J269 for open circuit, short circuit, and poor contact. If no problems are found, replace the Tray 1 Feed/Nudger Motor (PL 13.2 Item 6). Measure the resistance between the MD PWB P/J525-B10/B11/B12/B13 and the Frame. Is the resistance infinite for all? Y↓ N→Check the wires of the pins with non-infinite resistance for peeled-off coatings and short circuits due to pinching. Replace the following parts in sequence: • MD PWB • MCU PWB Press the Stop button. Turn On DC330 [075-102] (Tray 1 Nudger Position Sensor). Move the Shielding Board to block/clear the light path to the Tray 1 Nudger Position Sensor. Does the display change between High/Low? Y↓ N→Use Transmissive Sensor RAP to check the Tray 1 Nudger Position Sensor. Press the Stop button and turn the power Off. Check the Tray 1 Nudger Roll Up/Down mechanism for mechanical loading, the springs for deformation or snags. If no problems are found, replace the following parts in sequence: • MD PWB • MCU PWB