Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 389.617 — Xerox Phaser 7800

Code: 389.617

Description: RC Lead Regi Over Range Fail. The result from adding the offset value to the color registration correction value has exceeded the settable range. (This is a hidden failure. The Alignment Lead Regi or Skew might have exceeded the adjustable range and Data is only recorded in history.)
Remedy: 1. Check that the value of dc131 NVM Read/Write [760-063] is "0". (Because this Fail occurs only when the NVM write data is incorrect or the NVM is corrupted, if the setting value is not "0", reset it to "0".) 2. Check that the value of DC131 [760-082] is between the values of DC131 [760-084] and DC131 [760-085]. (If it is not, set the value of DC131 [760-082] to be between the values of DC131 [760-084] and DC131 [760-085].) 3. Check that the value of DC131 [760-083] is between the values of DC131 [760-084] and DC131 [760-085]. (If it is not, set the value of DC131 [760-083] to be between the values of DC131 [760-084] and DC131 [760-085].)

← Xem tất cả mã lỗi Xerox Phaser 7800

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin