Code: 393.324
Description: Dev Y, M, C Motor Fault. The Dev Motor (Y, M, C) revolution failure was detected.
Remedy: Turn the power Off and remove the Front Cover. Remove the Imaging Unit (Y, M, C) and the Developer (Y, M, C) and cheat the Front Cover Interlock Switch. Turn the power On and enter Service Diag mode (Entering Service Diagnostics). Turn On dc330 Component Control [093-022] (Dev Drive Motor Y, M, C). Does the Dev Drive Motor (Y, M, C) rotate? Y↓ N→Turn the power Off and remove the Rear Upper Cover. Turn the power On. Is the voltage between the MD PWB P/J526-7 (+) and the GND (-) +24VDC? Y↓ N→Go to +24VDC Power RAP. Is the voltage between the MD PWB P/J527-B16 (+) and the GND (-) +5VDC? Y↓ N→Go to +5VDC Power RAP. Turn the power Off and check the connections between the MD PWB P/J526 and the Dev Drive Motor (Y, M, C) P/J251, as well as between the MD PWB P/J527 and the Dev Drive Motor (Y, M, C) P/J252 for open circuits, short circuits, and poor contacts. If no problems are found, replace the following parts in sequence: • Dev Drive Motor (Y, M, C) (PL 3.3) • MD PWB • MCU PWB Press the Stop button and turn the power Off. Install the Drum (Y, M, C), the Developer (Y, M, C), and the Front Cover. Turn the power On and enter Service Diag mode. Turn On dc330 Component Control [093- 022] (Dev Drive Motor Y, M, C). Does the Dev Drive Motor (Y, M, C) rotate? Y↓ N→Check the Developer (Y, M, C) for loading. Press the Stop button and turn the power Off. Check the connection between the Dev Drive Motor (Y, M, C) P/J252-8 and the MD PWB P/J527-B9 for open circuit, short circuit, and poor contact. If no problems are found, replace the following parts in sequence: • MD PWB • MCU PWB