Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 394.323 — Xerox Phaser 7800

Code: 394.323

Description: 2nd BTR Contact/Retract Fault. After the 2nd BTR Contact/Retract operation has started, it does not complete within the specified time.
Remedy: Turn the power On and enter the Diag mode. Turn On dc330 Component Control [094-201]. Move the Shielding Board of the 2nd BTR Contact Retract Sensor manually to block/clear the light path to the 2nd BTR Contact Retract Sensor. Does the display change between High/ Low? Y↓ N→Use Transmissive Sensor to fix the 2nd BTR Contact Retract Sensor. Press the Stop button. Turn On DC330 [094-003] (Contact) and DC330 [094-004] (Retract) alternately. Does it contact/retract? Y↓ N→Remove the IBT and check the following: • The 2nd BTR Contact Retract Gear for wear, damage, and revolution failure • The 2nd BTR Contact Retract Motor for improper installation • The 2nd BTR Contact Retract Sensor for improper installation • The connection between the 2nd BTR Contact Retract Motor P/J280 and the MD PWB P/J523 for open circuit, short circuit, and poor contact If no problems are found, replace the 2nd BTR Contact Retract Motor (PL 14.4). Press the Stop button and turn the power Off. Replace the following parts in sequence: • MD PWB • MCU PWB

← Xem tất cả mã lỗi Xerox Phaser 7800