Code: 13,1XX.4x
Description: Left Jetstack Thermal Faults A thermal error in the Printhead jetstack has occurred. The following troubleshooting procedures apply to these errors: 13,136.49 The left jetstack heater is too hot. 13,138.42 The left jetstack heater took too long to reach the setpoint temperature. 13,195.45 The left jetstack heater thermistor circuit is open. 13,197.47 The left jetstack heater thermistor circuit is shorted. 13,199.49 The left jetstack heater thermistor returned faulty reading.
Causes: Printhead, PL 2.0 Electronics Module -
Remedy: • Check that all system grounds are secured. • Check the ambient room temperature. • Check the fan operation and vents. • If the problem persists, follow the procedure below.
1 Verify that the ambient temperature of the room is within the system’s specifications. Is the room within operating parameters? Go to Step 2. Advise the customer of operational requirements. 2 Check ground integrity for the printer. Does the error persist? Go to Step 3. Complete. 3 Test the Left Jetstack. Run the Service Diagnostics Left Jetstack Temperature test. Does the Preheater operate correctly? Go to Step 4. Replace the Printhead. 4 Check Printhead connections and wiring. Are the connections secure and the wiring undamaged? Replace the Printhead. Repair the wiring.
1 Verify that the ambient temperature of the room is within the system’s specifications. Is the room within operating parameters? Go to Step 2. Advise the customer of operational requirements. 2 Check ground integrity for the printer. Does the error persist? Go to Step 3. Complete. 3 Test the Left Jetstack. Run the Service Diagnostics Left Jetstack Temperature test. Does the Preheater operate correctly? Go to Step 4. Replace the Printhead. 4 Check Printhead connections and wiring. Are the connections secure and the wiring undamaged? Replace the Printhead. Repair the wiring.