Code: 37,03X.4x
Description: PEST X-Axis Motor Faults An X-Axis Motor error has occurred. The following troubleshooting procedure applies to these errors: 37,030.45 The X-Axis Motor is drawing less power than expected. 37,031.46 The X-Axis Motor first phase is drawing less power than expected. 37,032.47 The X-Axis Motor first phase is drawing too much power. 37,033.48 The X-Axis Motor second phase is drawing less power than expected. 37,034.40 The X-Axis Motor second phase is drawing too much power.
Causes: X-Axis Motor, PL 4.0 Right Side Harness / I/O Control - Electronics Module, PL 5.0 Right Side Wire Routing (2/2) -
Remedy: • Check the X-Axis Motor connection. • If the problem persists, follow the procedure below.
1 Test the X-Axis Motor. Run the Service Diagnostics X-Axis Drive test. Does the motor operate correctly? Replace the Electronics Module. Go to Step 2. 2 Check wiring to the motor. Is the wiring damaged? Repair or replace the harness. Replace the X-Axis Motor.
1 Test the X-Axis Motor. Run the Service Diagnostics X-Axis Drive test. Does the motor operate correctly? Replace the Electronics Module. Go to Step 2. 2 Check wiring to the motor. Is the wiring damaged? Repair or replace the harness. Replace the X-Axis Motor.