Mã lỗi 4,0xx.4x — Xerox Phaser 8400

Code: 4,0xx.4x

Description: Process Control Errors. The following troubleshooting procedure applies to these errors: 4,017.47 The ambient temperature is too low ( < 10°C). 4,018.48 The Printhead temperature is too low. 4,020.41 Fast Time To Ready (FTTR) mode with head/cap flag set in NVRAM. 4,021.42 Fast Time To Ready (FTTR) mode with a dirty Drum.
Causes: Electronics Module, PL 5.0 Right Side Wire Routing (2/2) - Printhead, PL 2.0 Electronics Module - Drum Assembly, PL 2.0 Electronics Module Power - Drum Heater Relay Board, PL 5.0 Right Side Wire Routing (1/2) - Drum Temperature Sensor, PL 6.0 I/O Board (2/2) -
Remedy: • Check the ambient air temperature. • Check that the system is located in a suitable environment. • If the problem persists, follow the procedure below.
1 Test the heaters. Run the Service Diagnostics Monitor Heaters tests with all heaters On. Do the heaters function properly? Replace the Electronics Module. Go to Step 3. 2 Check the harness to the failed heater. Is the harness damaged? Replace the harness. Replace the failed component.