Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 13,00x.6x — Xerox Phaser 8500

Code: 13,00x.6x

Description: Thermal Program Faults A software error has occurred. The following troubleshooting procedure applies to these errors: 13,001.62 Thermals failed to read system NVRAM. 13,002.63 Value not in valid range. 13,003.64 Thermal control task received an unexpected message. 13,004.65 Thermal control task was expecting initialization message, but received other. 13,005.66 Thermal code tried to command a segment ID that did not exist. 13,006.67 Thermal code tried to command a segment ID that did not exist. 13,007.68 Thermal power manager expected an initialization message, but received other. 13,008.60 Thermal power manager task received an unexpected message.
Causes: NVRAM, PL 5.0
Remedy: • Reset NVRAM and retest. • If the problem persists, follow the procedure below.
1 Reseat all Electronics Module connections. Does the problem persist? Go to Step 2. Complete. 2 Check ground integrity. Are the system grounds connected? Reset NVRAM. If the error persists, replace the NVRAM device. Reconnect the system grounds.

← Xem tất cả mã lỗi Xerox Phaser 8500

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie