Code: 19,0XX.4x
Description: Printhead Calibration Faults The root problem for this error is temperature sensitivity with the power supply’s opto-isolator chips. The following troubleshooting procedure applies to this error: 19,001.46 The HFD server failed due to NVRAM operation. THis fault should only occur when the system is in manufacturing mode. 19,002.47 The system attempted a Printhead operation without position data in NVRAM. 19,003.48 Scale and offset voltage error too large. Something is wrong with the Electronics Module or Wave Amplifier. 19,004.40 The Printhead and Electronics Module do not match. 19,005.41 Improper ground connection
Causes: Electronics Module, PL 5.0 Electronics Module - Printhead, PL 2.0 Electronics Module -
Remedy: • Check electrical connections to the Printhead. • Check for obstructions or damage near the Printhead. If obstructions are cleared, retest. • If the problem persists, follow the procedure below.
1 Check and reseat all connections to the Printhead. Does the problem persist? Replace the Printhead. If the error persists, replace the Electronics Module. Complete.
1 Check and reseat all connections to the Printhead. Does the problem persist? Replace the Printhead. If the error persists, replace the Electronics Module. Complete.