Code: 37,02X.4x
Description: PEST Relay Board Faults An Relay Board error has occurred. The following troubleshooting procedure applies to these errors: 37,027.45 Both relay coils are drawing less power than expected. 37,028.46 The A coil is drawing less power than expected. 37,029.47 The B coil is drawing less power than expected.
Causes: Relay Board, PL 5.0 I/O Board (1/2) - Electronics Module, PL 5.0 Electronics Module Power -
Remedy: • Check the Relay Board’s power connection. • If the problem persists, follow the procedure below.
1 Test the Relay Board. Run the Service Diagnostics Drum Heater Relay test. Does the Relay Board operate correctly? Replace the Electronics Module. Go to Step 2. 2 Check wiring to the affected component. Is the wiring damaged? Repair or replace the harness. Replace the Relay Board.
1 Test the Relay Board. Run the Service Diagnostics Drum Heater Relay test. Does the Relay Board operate correctly? Replace the Electronics Module. Go to Step 2. 2 Check wiring to the affected component. Is the wiring damaged? Repair or replace the harness. Replace the Relay Board.