Code: 13,008.47, 13,010.49
Description: Drum Thermal Faults A Drum Assembly thermal error has occurred. The following troubleshooting procedures apply to these errors: 13,008.47 The Drum Heater is too hot 13,010.49 The Drum Heater took too long to reach the setpoint temperature.
Causes: Drum Fan, PL 4.0 Right Side Harness / I/O Control - Drum Assembly Electronics Module Power - Drum Temperature Sensor, PL 6.0 I/O Board (2/2) - Electronics Module Fan Left Side Harness (2/2) -
Remedy: • Check that all system grounds are secured. • Check the ambient room temperature. • Check the fan operation and vents. • If the problem persists, follow the procedure below.
1 Verify that the ambient temperature is within environmental specifications. Is the room within operating parameters? Go to Step 2. Advise the customer of operational requirements. 2 Check ground integrity for the printer. Does the error persist? Go to Step 2. Complete. 3 Is the error code associated with an overheat condition?. Go to Step 4. Go to Step 6. 4 Check airflow at the vents. Is there adequate clearance, and are the vents clean? Go to Step 5. Clean the vents. 5 Test the Drum Fan Run the Service Diagnostics Drum Fan Motor test. Does the fan operate correctly? Go to Step 6. Replace the Drum Fan. 6 Test the Electronics Module Fan. Does the Fan operate correctly? Go to Step 7. Replace the Electronics Module Fan. 7 Test the Drum Temperature Sensor. Run the Service Diagnostics Drum Temperature Sensor test. Does the sensor operate correctly? Go to Step 8. Replace the Drum Temperature Sensor.. 8 Test the Drum Heater. Run the Service Diagnostics Drum Heater test. Does the heater operate correctly? Replace the Drum Assembly. Replace the Drum Temperature Sensor..
1 Verify that the ambient temperature is within environmental specifications. Is the room within operating parameters? Go to Step 2. Advise the customer of operational requirements. 2 Check ground integrity for the printer. Does the error persist? Go to Step 2. Complete. 3 Is the error code associated with an overheat condition?. Go to Step 4. Go to Step 6. 4 Check airflow at the vents. Is there adequate clearance, and are the vents clean? Go to Step 5. Clean the vents. 5 Test the Drum Fan Run the Service Diagnostics Drum Fan Motor test. Does the fan operate correctly? Go to Step 6. Replace the Drum Fan. 6 Test the Electronics Module Fan. Does the Fan operate correctly? Go to Step 7. Replace the Electronics Module Fan. 7 Test the Drum Temperature Sensor. Run the Service Diagnostics Drum Temperature Sensor test. Does the sensor operate correctly? Go to Step 8. Replace the Drum Temperature Sensor.. 8 Test the Drum Heater. Run the Service Diagnostics Drum Heater test. Does the heater operate correctly? Replace the Drum Assembly. Replace the Drum Temperature Sensor..