Description: Adjustment error of head management sensor position (support number : 4801)
Causes: Adjusting head management sensor position is failed.
Remedy: 1 Check if the ink is filled into ink tubes. Ink is filled Go to 2. Ink is not filled Perform [DIAGNOSIS > PURGE CHECK] to diagnose ink vacuum of PURGE UNIT. PURGE UNIT ink vacuum diagnosis Proper operation Perform deep cleaning and fill the ink. When the ink vacuum does not recover, replace the print head. Abnormal operation Replace PURGE UNIT. 2 Print user nozzle check pattern or service nozzle check pattern to check the nozzle condition. (Check if blur or non-ejection appears at the top and bottom edge line of the nozzle check pattern.) Appropriate condition Replace HEAD MANAGEMENT SENSOR UNIT. Abnormal condition Perform deep cleaning and fill the ink. When the ink vacuum does not recover, replace the print head.