Code: 37,039.48, 37,040.40
Description: PEST Process Drive Faults A Y-Axis Motor error has occurred. The following troubleshooting procedure applies to these errors: 37,039.48 The Process Drive Motor is drawing less power than expected. 37,040.40 The Process Drive Motor is drawing too much power.
Causes: Process Drive, PL 4.0 Right Side Harness / I/O Control - Electronics Module, PL 5.0
Remedy: • Check for obstructions to Process Drive rotation. • Check the rotation of the Drum Maintenance and Transfix Roller shafts. • If the problem persists, follow the procedure below.
1 Check shaft rotation. Do the Process Drive gears, Transfix Shaft, and Drum Maintenance shaft rotate freely? Go to Step 2. Repair or replace affected parts. 2 Test the Process Drive Motor. Run the Service Diagnostics Process Motor test. Does the motor operate correctly? Replace the Electronics Module. Go to Step 3. 3 Check wiring to the motor. Is the wiring damaged? Repair or replace the harness. Replace the Process Drive.
1 Check shaft rotation. Do the Process Drive gears, Transfix Shaft, and Drum Maintenance shaft rotate freely? Go to Step 2. Repair or replace affected parts. 2 Test the Process Drive Motor. Run the Service Diagnostics Process Motor test. Does the motor operate correctly? Replace the Electronics Module. Go to Step 3. 3 Check wiring to the motor. Is the wiring damaged? Repair or replace the harness. Replace the Process Drive.