Code: 13,067.43, 13,069.45, 13,071.47
Description: Drum Temp Sensor Faults A Drum Temperature Sensor error has occurred. The following troubleshooting procedures apply to these errors: 13,067.43 The Drum Thermistor circuit is open. 13,069.45 The Drum Thermistor circuit is shorted. 13,071.47 The Drum Thermistor returned faulty reading.
Causes: Drum Temperature Sensor, PL 6.0 I/O Board (2/2) -
Remedy: • Check that all system grounds are secured. • Check the ambient room temperature. • Check the fan operation and vents. • If the problem persists, follow the procedure below.
1 Test the Drum Temperature Sensor. Run the Service Diagnostics Drum Temperature Sensor test. Does the sensor operate correctly? Go to Step 2. Replace the Drum Temperature Sensor.. 2 Check the Drum Heater Sensor harness. Is the harness free from defects or damage? Replace the Drum Temperature Sensor.. Repair the wiring.
1 Test the Drum Temperature Sensor. Run the Service Diagnostics Drum Temperature Sensor test. Does the sensor operate correctly? Go to Step 2. Replace the Drum Temperature Sensor.. 2 Check the Drum Heater Sensor harness. Is the harness free from defects or damage? Replace the Drum Temperature Sensor.. Repair the wiring.