Code: 2,006.xx
Description: I/O Board Program Faults The following troubleshooting procedure applies to these errors: 2,001.69 The Electronics Module Failed to initialize. 2,002.61 Firmware program fault 2,003.62 Firmware program fault 2,004.63 Failure to start the Print Engine in Suspend Mode. 2,005.64 ROM read error 2,006.65 ROM read error 2,007.66 idiags entry point access error
Causes: I/O Board, PL 5.0.13 NVRAM, PL 5.0.9
Remedy: • Reset NVRAM and retest. • Check that all connections to the Electronics Module and I/O Board are secure by reseating each connection. • If the problem persists, follow the procedure below.
1 Reseat all I/O Board connections. Does the problem persist? Go to Step 2. Complete. 2 Reseat all Electronics Module connections. Does the problem persist? Go to Step 3. Complete. 3 Check ground integrity. Are the system grounds connected? Replace the NVRAM device. Reconnect the system grounds.
1 Reseat all I/O Board connections. Does the problem persist? Go to Step 2. Complete. 2 Reseat all Electronics Module connections. Does the problem persist? Go to Step 3. Complete. 3 Check ground integrity. Are the system grounds connected? Replace the NVRAM device. Reconnect the system grounds.