Code: 36,000.40
Description: Drum Maintenance Faults An error occurred while attempting to position the Drum Maintenance Kit. The following troubleshooting procedure applies to these errors: 36,000.40 An error occurred while attempting to position the Drum Maintenance Kit.
Causes: Drum Maintenance Kit PL 1.0 Drum Maintenance Pivot Plate PL 2.0 I/O Board (2/2) - Process Drive, PL 4.0 Right Side Harness / I/O Control -
Remedy: • Check for ink spills or obstructions near the Drum Maintenance Kit. • Check for obstructions or damage to the Pivot Plate and Cam Rollers. • If the problem persists, follow the procedure below.
1 Check that system grounds are in place. Are the grounds secure and undamaged? Go to Step 2. Repair or replace the grounds. 2 Check the Drum Maintenance Pivot Plate for cracks, and the Dram Maintenance Cam Rollers for damage or improper movement. Is there damage to the Pivot Plate or Cam Rollers? Replace any damaged parts. Go to Step 3. 3 Test Drum Maintenance operation. Run the Service Diagnostics Drum Maintenance/ Transfix Home test. Does the system operate correctly? Go to Step 4. Replace the Process Drive. 4 Test the Drum Maintenance drive. Run the Service Diagnostics Drum Maintenance Drive test. Does the drive operate correctly? Complete. Replace the Process Drive
1 Check that system grounds are in place. Are the grounds secure and undamaged? Go to Step 2. Repair or replace the grounds. 2 Check the Drum Maintenance Pivot Plate for cracks, and the Dram Maintenance Cam Rollers for damage or improper movement. Is there damage to the Pivot Plate or Cam Rollers? Replace any damaged parts. Go to Step 3. 3 Test Drum Maintenance operation. Run the Service Diagnostics Drum Maintenance/ Transfix Home test. Does the system operate correctly? Go to Step 4. Replace the Process Drive. 4 Test the Drum Maintenance drive. Run the Service Diagnostics Drum Maintenance Drive test. Does the drive operate correctly? Complete. Replace the Process Drive