Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 34,00X.4x — Xerox Phaser 8560

Code: 34,00X.4x

Description: Printhead NVRAM Faults The Printhead is unable to access system NVRAM. The following troubleshooting procedure applies to these errors: 34,001.43 An error occurred while attempting read/write access to the Printhead calibration partition in NVRAM. The Printhead cable may be unplugged. 34,002.44 An error occurred while attempting read/write access to the Printhead ink data partition in NVRAM. 34,003.45 An error occurred while attempting read/write access to the Printhead data partition in NVRAM. 34,004.46 An error occurred while accessing the Printhead NVRAM hardware for purposes of initialization. The Printhead cable may be unplugged.
Causes: Printhead, PL 2.0 Electronics Module - Printhead Interface Cable, PL 5.0 Electronics Module -
Remedy: • Check data connection to the Printhead. • Check for obstructions or damage to the Media Guides. • If the problem persists, follow the procedure below.
1 Check the Printhead data cable connections (P/J3 and P/J180). Are the connections secure and the cable undamaged? Go to Step 2. Repair or replace the cable. 2 Replace the Printhead. Does the error persist? Replace the Electronics Module. Complete.