Mã lỗi 6,0xx.6x — Xerox Phaser 8560

Code: 6,0xx.6x

Description: X-Axis Program Faults A software error has occurred. The following troubleshooting procedure applies to these errors: 6,001.64 The X-Axis task received an unexpected message. 6,002.65 Attempt to home X-Axis drive from wrong state. 6,008.62 Attempt to use X-Axis drive without initialization. 6,011.65 Attempt to service X-Axis drive in wrong state. 6,013.67 Unknown X-Axis program fault. 6,017.62 Attempt to drive X-Axis using wrong server. 6,018.63 Attempt to move with the X-Axis not initialized. 6,019.64 Attempt to move with the X-Axis not at home position. 6,023.68 Could not allocate memory for X-Axis parameters. 6,025.66 Attempt to home the X-Axis drive without initialization. 6,032.68 Unrecognized X-Axis motion. 6,033.60 Could not allocate memory for X-Axis move parameters.
Causes: NVRAM, PL 5.0
Remedy: • Reset NVRAM and retest. • If the problem persists, follow the procedure below.
1 Reseat all Electronics Module connections. Does the problem persist? Go to Step 2. Complete. 2 Check ground integrity. Are the system grounds connected? Reset NVRAM. If the error persists, replace the NVRAM device. Reconnect the system grounds.