Code: F2D ... F2X

Description: F2D F2F F2M F2N F2P F2Q F2R F2S F2T F2V F2W F2X The Front Door Interlock tripped during warming up. The Front Door Interlock tripped during fault state. The Front Door Interlock tripped during a pick from Tray 2. The Front Door Interlock tripped during a pick from Tray 3. The Front Door Interlock tripped during a pick from Tray 4. The Front Door Interlock tripped during a pick from Tray 1. The Front Door Interlock tripped during duplexing. The Front Door Interlock tripped while the paper was staged for transfix. The Front Door Interlock tripped during transfix. The Front Door Interlock tripped during Drum oiling. The Front Door Interlock tripped during imaging. The Front Door Interlock tripped during exit.
Causes:
Remedy: 1. Check the Front Door for damaged hinges, latch, or interlock actuator. 2. Check the covers for proper alignment and fit. 3. Test the Interlock Switch (Door Sensor test) using Service Diagnostics. 4. Check the Front Door Interlock Switch installation and wiring. 5. Replace the switch, then retest.