Code: 13,XXX.xx
Description: Printhead Reservoir Thermal Faults A Printhead Reservoir thermal error has occurred. The following troubleshooting procedures apply to these errors: 13,264.42 The Printhead reservoir heater is too hot. 13,266.44 The Printhead reservoir heater took too long to reach setpoint temp. 13,323.47 The Printhead reservoir heater thermistor circuit is open. 13,325.49 The Printhead reservoir heater thermistor circuit is shorted. 13,327.42 The Printhead reservoir heater thermistor returned faulty reading.
Causes: Printhead, PL 2.0 Electronics Module -
Remedy: • Check that all system grounds are secured. • Check the ambient room temperature. • Check the fan operation and vents. • If the problem persists, follow the procedure below.
1 Verify that the ambient temperature of the room is within the system’s specifications. Is the room within operating parameters? Go to Step 2. Advise the customer of operational requirements. 2 Check ground integrity for the printer. Does the error persist? Go to Step 3. Complete. 3 Test the Printhead Reservoir temperature. Run the Service Diagnostics Reservoir Temperature test. Does the Printhead operate correctly? Go to Step 4. Replace the Printhead. 4 Check Printhead connections and wiring. Are the connections secure and the wiring undamaged? Replace the Printhead. Repair the wiring.
1 Verify that the ambient temperature of the room is within the system’s specifications. Is the room within operating parameters? Go to Step 2. Advise the customer of operational requirements. 2 Check ground integrity for the printer. Does the error persist? Go to Step 3. Complete. 3 Test the Printhead Reservoir temperature. Run the Service Diagnostics Reservoir Temperature test. Does the Printhead operate correctly? Go to Step 4. Replace the Printhead. 4 Check Printhead connections and wiring. Are the connections secure and the wiring undamaged? Replace the Printhead. Repair the wiring.