Code: 13,XXX.4x
Description: Preheater Thermal Faults A Preheater thermal error has occurred. The following troubleshooting procedures apply to these errors: 13,072.48 The Preheater is too hot. 13,074.41 The Preheater took too long to reach the setpoint temperature. 13,131.44 The Preheater Thermistor circuit is open. 13,133.46 The Preheater Thermistor circuit is shorted. 13,135.48 The Preheater Thermistor returned faulty reading
Causes: Preheater, PL 2.0 I/O Board (1/2) - I/O Board, PL 5.0 I/O Board (1/2) - Right Combined Cable, PL 5.0
Remedy: • Check that all system grounds are secured. • Check the ambient room temperature. • Check the fan operation and vents. • If the problem persists, follow the procedure below.
1 Verify that the ambient temperature of the room is within the system’s environmental specifications. Is the room within operating parameters? Go to Step 2. Advise the customer of operational requirements. 2 Test the Preheater. Run the Service Diagnostics Preheater test. Does the Preheater operate correctly? Replace the I/O Board. Go to Step 3. 3 Check Preheater connections and wiring. Are the connections secure and the wiring undamaged? Replace the Preheater. Repair or replace the wiring.
1 Verify that the ambient temperature of the room is within the system’s environmental specifications. Is the room within operating parameters? Go to Step 2. Advise the customer of operational requirements. 2 Test the Preheater. Run the Service Diagnostics Preheater test. Does the Preheater operate correctly? Replace the I/O Board. Go to Step 3. 3 Check Preheater connections and wiring. Are the connections secure and the wiring undamaged? Replace the Preheater. Repair or replace the wiring.