Code: 36,001.67
Description: Drum Maintenance Drive Faults An error occurred while attempting to position the Drum Maintenance Kit. The following troubleshooting procedure applies to this error: 36,001.67 An error occurred while attempting to position the Drum Maintenance Kit.
Causes: Drum Maintenance Kit PL 1.0 Drum Maintenance Pivot Plate PL 2.0 I/O Board (2/2) -
Remedy: • Check for ink spills or obstructions near the Drum Maintenance Kit. • Check for obstructions or damage to the Pivot Plate and Cam Rollers. • If the problem persists, follow the procedure below.
1 Check that system grounds are in place. Are the grounds secure and undamaged? Go to Step 2. Repair or replace the grounds. 2 Test Drum Maintenance operation. Run the Service Diagnostics Drum Maintenance/ Transfix Home test. Does the system operate correctly? Go to Step 3. Replace the Process Drive. 3 Test the Drum Maintenance drive. Run the Service Diagnostics Drum Maintenance Drive test. Does the drive operate correctly? Replace the Drum Maintenance Pivot Plate and Shaft. Replace the Process Drive
1 Check that system grounds are in place. Are the grounds secure and undamaged? Go to Step 2. Repair or replace the grounds. 2 Test Drum Maintenance operation. Run the Service Diagnostics Drum Maintenance/ Transfix Home test. Does the system operate correctly? Go to Step 3. Replace the Process Drive. 3 Test the Drum Maintenance drive. Run the Service Diagnostics Drum Maintenance Drive test. Does the drive operate correctly? Replace the Drum Maintenance Pivot Plate and Shaft. Replace the Process Drive