Code: 5,0xx.6x
Description: Y-Axis Sub-System Program Faults A software error has occurred. The following troubleshooting procedure applies to these errors: 5,001.63 Y-Axis sub-system general fault. 5,005.67 Sub-system not in homeless or idle state, software fault. 5,006.68 Software fault. 5,007.60 Software fault. 5,008.61 PostScript failed to fill the buffer. 5,009.62 Imaging errors. Possible jets On/Off outside the deadband area.
Causes: NVRAM, PL 5.0
Remedy: • Reset NVRAM and retest. • If the problem persists, follow the procedure below.
1 Reseat all Electronics Module connections. Does the problem persist? Go to Step 2. Complete. 2 Check ground integrity. Are the system grounds connected? Reset NVRAM. If the error persists, replace the NVRAM device. Reconnect the system grounds.
1 Reseat all Electronics Module connections. Does the problem persist? Go to Step 2. Complete. 2 Check ground integrity. Are the system grounds connected? Reset NVRAM. If the error persists, replace the NVRAM device. Reconnect the system grounds.