Mã lỗi 05-100 — Xerox WorkCentre 3550

Code: 05-100

Description: DADF Jam 1
Causes: The lead edge of the document failed to actuate the scan sensor within the correct time after registration solenoid actuation.
Remedy: 1. Open the DADF door assembly . Remove all jammed paper. 2. Check the document path for damage or obstructions. 3. Check that the following components are clean and rotate freely: • Registration roll . • Registration roll idlers . 4. Remove the transport assembly upper cover . 5. Check that the DADF scan sensor actuator moves freely and is not damaged. 6. Enter dC330 code 05-140. Check the scan sensor (Q05-140) . If necessary, install a scan sensor. 7. Check the wiring between the DADF scan sensor and CN1 on the DADF PWB. 8. Remove the DADF rear cover . Enter dC330 code 05-200. Check that the DADF scan motor runs. 9. Check the wiring between the DADF scan motor and CN9 on the DADF PWB. 10. Open the DADF door assembly . Manually actuate the DADF door open sensor . While the DADF scan motor runs, stack the code 05-310 to energize the DADF registration solenoid (SOL05-310). Check that the registration roll rotates. 11. Check the wiring between the DADF registration solenoid and CN8 on the DADF PWB. 12. If necessary, install new components: • DADF PWB . • DADF scan motor . • DADF registration solenoid . • DADF drive assembly . • Document transport assembly .

← Xem tất cả mã lỗi Xerox WorkCentre 3550

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie