Code: OF2
Description: UI Touch Screen Error
Causes: Use this RAP to solve UI touch screen problems when the machine has power but either the display is missing, is too dark or the UI screen responds incorrectly or does not refresh.
Remedy: 1. If possible, enter dC305 UI test. Perform the relevant tests to check the operation of the UI. 2. Remove the UI, refer to REP 2.1. Check the ribbon cables between the UI PWB and the touch screen . 3. Check the following wiring: • Between CN2 on the UI PWB and CN6 on Main PWB. • Between CN1 on the UI PWB and CN11 on Main PWB. • Between CN11 on the UI PWB and CN10 on Main PWB. 4. If necessary: a. Install new components: • Touch screen . • UI assembly . b. Perform OF7 Main PWB Check RAP.